FIXED FREQUENCY WIRELESS POTENTIOSTAT

Pinnacle’s FIXED FREQUENCY WIRELESS POTENTIOSTAT SYSTEM is designed for experimental models that require simultaneous recording of 1-3 animals. Each basestation (#8106) can communicate with one potentiostat (#8151).

Pinnacle’s fixed frequency wireless potentiostat system is recommended for 1-3 simultaneous in vivo biosensor recordings and utilizes a one-to-one ratio of basestation to potentiostat per animal.

Each system uses Pinnacle’s headmounted “Rat Hat” to enclose a stereotaxically-placed guide cannula, a potentiostat, and an implanted biosensor. Pinnacle’s acquisition software is included at no extra charge.

WIRELESS DIGITAL TRANSMISSION

SIMPLE TO USE

REAL-TIME RESULTS

SECOND-BY-SECOND RECORDINGS

SYSTEM OVERVIEW

The “Rat Hat” top encloses and protects the system allowing for group housing and behavioral experiments.

The 8151 wireless 2-channel potentiostat applies a bias and transmits up to 2 digitized signals to an 8106 basestation.

Pinnacle’s signature “Rat Hat” system is used to house the electronics, battery, guide cannula and biosensor and is affixed to the skull via dental acrylic. The “Rat Hat”, potentiostat, biosensor and battery weigh at total of 8.7 grams.

Stereotaxically placed guide cannulas allow for insertion of biosensors post-surgery.

Each 8106 can communicate with one potentiostat and is recommended for 1-3 simultaneous in vivo biosensor recordings. Basestations interface with Pinnacle’s acquisition software on a Windows based PC via USB. The basestation has a 3 meter transmission radius and transmits by radio frequency on the 916 Hz band (US) or 868 Hz band (EU).

FIXED FREQUENCY SYSTEM SPECS

3 METER TRANSMISSION RADIUS:

TOTAL WEIGHT OF HEADMOUNTED SYSTEM: 8.7 grams with   battery

BATTERY LIFETIME:~72hrs

8151 POTENTIOSTAT SPECS:

• RF BAND: 916Mhz ISM (NA), 868Mhz ISM (EU)

• 2 CHANNEL

• 2 TERMINAL

• SAMPLING RATE: 1 Hz

• FACTORY SET GAIN

• CURRENT RANGE: Bias & Gain dependent (0 -> 250 nA @ 5,000,000V/A and 0.6V range)

• RESOLUTION: 24 bits

• SENSITIVITY: 30 fA

• BIAS RANGE: 0 -> 1.5 volts

8100 FIXED FREQUENCY SYSTEM

8100-K1: FIXED FREQUENCY WIRELESS POTENTIOSTAT SYSTEM

CONTENTS

8151: Programmable wireless potentiostat (headmount)

8106: Base station for wireless potentiostat

  Also included: cables for one animal, software and manuals

DISPOSABLES & ACCESSORIES: FIXED FREQUENCY read more >>

  • DISPOSABLES

  • Pinnacle’s wireless biosensor system employs our signature “Rat Hat” system which is used to house the electronics, battery, guide cannula and biosensor. The bottom portion of the “Rat Hat” (#8108-S1) is affixed to the skull via anchor screws and dental acrylic. A rectangular 13 mm X 9 mm opening surrounds the guide cannula(s). An alternative “Rat Hat” bottom (#8108-R1) with a 9 mm diameter round opening is available as well. Bottoms are not reusable.


    Pinnacle’s wireless biosensor system employs our signature “Rat Hat” system which is used to house the electronics, battery, guide cannula and biosensor. The top portion of the “Rat Hat” (#8107-S1) encloses and protects the system. A single hex screw secures the hat and can be tightened during conscious applications.


    Pinnacle offers 1/8” stainless steel bone screws to act as anchors for the “Rat Hat” system. It is recommended to utilize three screws to securely affix the “Rat Hat” bottom and guide cannula(s).


    Coin cell (3V) volt batteries power the wireless potentiostat. Battery life span is estimated at 72 hrs when used continuously.


    Stereotaxically placed guide cannulas allow for insertion of biosensors post-surgery. For single biosensor implantations in rats the BASi rat guide cannula (#7030) is recommended for use. The 7030 guide cannula shaft is 10mm in length and approximately 560 uM in diameter. Pinnacle’s 7002 standard biosensor electrodes are compatible with the BASi rat guide cannula. Guide cannulas are not reusable.


    Stereotaxically placed guide cannulas allow for insertion of biosensors post-surgery. For dual biosensor implantations in rats the BASi mouse guide cannula (#7032) is recommended for use. The 7032 guide cannula shaft is 5 mm in length and approximately 600 uM in diameter. The smaller size of the cannula allows for contralateral implantation of biosensors at a minimum distance of approximately 3.2 mm Pinnacle’s 7004 standard biosensor electrodes are compatible with the BASi mouse guide cannula. Guide cannulas are not reusable.

    ACCESSORY KIT FOR BASi GUIDE CANNULA SYSTEM

    Pinnacle offers accessory kits for purchase that include all accesories necessary to complete setup as well as components needed for four surgeries. All quantities are (1) unless otherwise noted by a (#) after the product description.



    8100-K3-BAS       Fixed Frequency Wireless Potentiostat

    8107-S1: “Rat Hat” top

    8108-S1: “Rat Hat” bottom (4)

    8147-A: Hex screwdriver

    8111: Bone screws (12)

    8112: Drill bit

    7035-R-BAS: Probe holder for BASi
    rat cannula

    7030: BASi cannula for rats (4)

    9005: 7-Port powered USB hub

    8152: Batteries for 8151 (Pack of 5)

    8154: 8162 template

    8134: Test load (2)

    8127: Programmer

    8141-S: Screwdriver for bone screws